EAS documents

Read technical documents online and download the source files for the models and configurations they cover.

AS7019 Check the door panel before closing it - prepared reference

The doorway assembly needs a suitable non-metallic panel area and access to the matching supply and controller. Test the antenna in its intended panel position before completing the door frame; a working bench test does not account for metal around the installed opening.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS7002 WD666 per-channel diagnostics - prepared reference

The WD666 menu distinguishes each channel's signal value, environmental-noise value and accumulated strong-interference events. Use the relevant reading to decide whether a persistent alarm follows a nearby tag, an affected channel or site interference.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4041 Separate local setup from remote access - prepared reference

Local Wi-Fi setup connects the compatible application to the controller. Remote diagnostics additionally require the installed controller to reach its supported service through the site network; local connectivity alone does not prove remote service is available.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4028 AMS9060 antenna configuration - English

Review system noise and each antenna independently in the configurator. Coil-processing modes affect the noise response, so choose the configuration for the actual connected antenna rather than applying a universal sensitivity setting.

Document
Manual
Language
en

AS4028 AMS9060 antenna configuration - prepared reference

Review system noise and each antenna independently in the configurator. Coil-processing modes affect the noise response, so choose the configuration for the actual connected antenna rather than applying a universal sensitivity setting.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4028 AMS9060 controller installation - English

Plan the indoor controller position and the required antenna channels before mounting. The installation guide provides shelf, wall and ceiling arrangements, cable entries and strain relief for the illustrated controller.

Document
Manual
Language
en

AS4028 AMS9060 controller installation - Chinese

Plan the indoor controller position and the required antenna channels before mounting. The installation guide provides shelf, wall and ceiling arrangements, cable entries and strain relief for the illustrated controller.

Document
Manual
Language
zh-CN

AS4018 Preserve the S450 connection layout - prepared reference

The S450 guide plans supply routing to the host separately from the conduits between host and auxiliary positions. Record the connection order before extending or reconnecting those leads, and have the actual mains and pedestal wiring completed against the supplied drawing.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4017 F22 controller function reference - prepared reference

The dated Chinese function sheet covers channel roles, software gain, hardware range, dynamic threshold and synchronization. Inspect the relevant channel signal/noise reading before changing sensitivity.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4017 F22 stationary-tag and outer-side settings - prepared reference

The F22 controller distinguishes moving tags from a tag left near the antenna. Its stationary-tag recognition can stop repeated alarms from the same unmoving tag; it is not a substitute for keeping tagged stock out of the protected passage.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4007 TST1050 switch-based setup - English

The documented TST1050-Z master and TST1050-P slave use switch-selected setup for phase and per-channel sensitivity. After an adjustment, return the relevant setup switch to its operating position to save the selection.

Document
Manual
Language
en
Version
V1.3

AS4007 TST1050 switch-based setup - Chinese

The documented TST1050-Z master and TST1050-P slave use switch-selected setup for phase and per-channel sensitivity. After an adjustment, return the relevant setup switch to its operating position to save the selection.

Document
Manual
Language
zh-CN
Version
V1.3

AS4004 S160 host and auxiliary arrangement - prepared reference

The S160 arrangement has a host controller and up to two auxiliary antenna positions. An auxiliary assembly is not a standalone replacement for the host; choose the actual transmitting, receiving or combined layout before channel setup.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AS4002 A91 controller menu reference - English

The original is a scanned controller menu rather than a text installation manual. It distinguishes channel roles, gain, synchronization and confirmation controls; use the illustration only when the supplied controller and firmware match.

Document
Manual
Language
en

AS4002 A91 controller commissioning - Chinese

The controller separates channel tag signals, environmental noise and alarm indicators. Inspect those readings before selecting gain or threshold, and verify the controller's running/network indicators before using the supported local setup application.

Document
Manual
Language
zh-CN

AS1002 Commission the AM and RF sections separately - prepared reference

The dual-system assembly contains separate AM and RF sections and their corresponding supplies. Prove each section with its own active tags before testing the combined entrance; an alarm from one technology is not evidence that the other has been commissioned.

Document
Guide
Language
en
Version
2026-11-05 prepared reference

AHD007 Selecting the inspection task - Chinese and English

Choose detection-only operation when an active label must remain active for a store check. Use the combined detection and deactivation position only when the checkout task requires the label to be deactivated.

Document
Manual
Language
mul

AD024 Embedded checkout installation - Chinese and English

AD024 is an embedded deactivation panel intended to become part of the checkout work surface. Plan its position around the labelled-item presentation path and keep the active area accessible to the cashier or shopper.

Document
Manual
Language
mul

AD014 Confirming the checkout result - English

The WD700X sheet uses both an audible response and panel indication to guide label presentation. A cashier should complete the pass through the active area and verify the result before moving the next item into the work area.

Document
Manual
Language
en

AD005 Checkout validation - English

Treat the WD300 reference as a controller-family guide. Its normal deactivation setting and detection-only setting serve different cashier tasks: a check in detection-only mode does not make a label inactive.

Document
Manual
Language
en

AD005 Checkout validation - Chinese

Treat the WD300 reference as a controller-family guide. Its normal deactivation setting and detection-only setting serve different cashier tasks: a check in detection-only mode does not make a label inactive.

Document
Manual
Language
zh-CN

Find the right document

Tell us the product model, hardware version and the information you need.

Contact our team